Technical data
Installation ◆ Air Supply Connections
18 310633C
6. For air spray, HVLP, and air-assist airless gun appli-
cations:
• Systems without a Gun Flush Box, connect
the gun air supply line between the Smart Fluid
Panel gun air outlet
(N - FIG. 9) and the
spray gun air inlet (AA - F
IG. 10).
• Systems with a Gun Flush Box, connect the
gun air supply line between the Smart Fluid
Panel gun air outlet
(N - FIG. 9) and the
atomizing air safety shutoff valve. See Gun
Flush Box Manual 310695.
CAUTION
The ProMix™ II potlife timer will not function properly
when used with multiple guns operating simultane-
ously. To avoid having mixed material set in the equip-
ment, carefully monitor potlife by some other means.
Install a bleed-type air shutoff valve (Z) in the gun
air supply line or at the gun air inlet (AA). F
IG. 10,
F
IG. 11.
WARNING
If using a Graco electrostatic PRO
™
Gun, a shutoff
valve must be installed in the gun air line. Contact your
Graco distributor for information on air shutoff valves
for electrostatic applications.
FIG. 9
FIG. 10
F
IG. 11
N
Z
AA
AA
U
CC
BB