10
3 Messages and safety component activation
3.1 Status messages of the barrier:
Here are the various status messages of the barrier (last line on the information screen):
Message
Meaning
« BARRIER OPEN »
The barrier is open and the automatic closing after the time delay or
auto mode are not activated
« BARRIER OPEN 15S »
The barrier is open and the barrier will close automatically at the end
of a countdown timer (Automatic closing after time delay and auto
mode activated)
Note: if the countdown timer remains at 15s, this means that an
order to open and/or a safety component is activated
« BARRIER CLOSED »
The barrier is closed
« OPENNING »
The barrier is in the process of opening
« CLOSING »
The barrier is in the process of closing
« DETECTION LOOP »
A vehicle is present on the safety loop.
Closing the barrier is impossible.
« DETECTION CELL »
A vehicle is present in front of the infrared or ultrasound cell(s).
Closing the barrier is impossible.
« BARRIER UNHINGED »
The barrier is unhinged.
The closing of the barrier is impossible if the option "Automatic
rehinging" is activated.
« CRANK MISSING »
The crank is not in its housing.
Controlling the barrier is impossible. The motor is cut off.
3.2 Messages for safety activation of the barrier:
Here are the various messages for safety activation of the barrier:
Message
Meaning
"Operation time exceeded"
The time for opening or closing the barrier has exceeded the
manoeuvring time (by default: 30s).
Motor control is cut off. The barrier has to be reset.
"Motor in fault
Error code: XXX"
The motor is in fault. The error code is indicated.
Error codes:
0: No error
106: Winding calculation error when powering up (motor
disconnected, short-circuit on the phases, incorrect configuration of
the motor, etc.)
107: Overheating of the IGBT module
Other: Contact After-Sales Service
"Fault while closing :
Obstacle detected"
The barrier has detected an obstacle during closing and has
automatically reopened and is held open. An opening order is
necessary to put it back into service
"Type of barreire unknown"
The parameterized barrier configuration is unknown. The
parameters must be set again: "Type_barriere",
"Longueur_lisse" and "Lisse".