Data Sheet

16
FORM NO.: FR2-015_ A Responsible DepartmentWBU Expiry Date: Forever
The information contained herein is the exclusive property of AzureWave and shall not be distributed, reproduced, or
disclosed in whole or in part without prior written permission of AzureWave.
Output delay time Identification mode
tODLY
0
50
ns
SDIO Bus Timing Parameters (Default Mode)
* min (VIH) = 0.7 × VDDIO and max (VIL) = 0.2 × VDDIO
SDIO Bus Timing (High-Speed Mode)
Parameter
Symbol
Minimum
Typical
Maximum
Unit
SDIO CLK (all values are referred to minimum VIH and maximum VIL
*
)
Frequency Data Transfer Mode
fPP
0
50
MHz
Frequency Identification Mode
fOD
0
400
kHz
Clock low time
tWL
7
ns
Clock high time
tWH
7
ns
Clock rise time
tTLH
3
ns
Clock low time
tTHL
3
ns
Inputs: CMD, DAT (referenced to CLK)
Input setup Time
tISU
6
ns
Input hold Time
tIH
2
ns
Outputs: CMD, DAT (referenced to CLK)
Output delay time Data Transfer Mode
tODLY
14
ns
Output hold time
tOH
2.5
ns
Total system capacitance (each line)
CL
40
pF