3.4 Host Interface
3.4.1 SDIO
SDIO Bus Timing (Default Mode)
Parameter
Symbol
Minimum
Typical
Maximum
Unit
SDIO CLK (All values are referred to minimum VIH and maximum VIL*)
Frequency Data Transfer mode
fPP
0
25
MHz
Frequency Identification mode
fOD
0
400
kHz
Clock low time
tWL
10
ns
Clock high time
tWH
10
ns
Clock rise time
tTLH
10
ns
Clock low time
tTHL
10
ns
Inputs: CMD, DAT (referenced to CLK)
Input setup time
tISU
5
ns
Input hold time
tIH
5
ns
Outputs: CMD, DAT (referenced to CLK)
Output delay time Data Transfer mode
tODLY
0
14
ns