Data Sheet

10
FORM NO.: FR2-015_ A Responsible DepartmentWBU Expiry Date: Forever
The information contained herein is the exclusive property of AzureWave and shall not be distributed, reproduced, or disclosed
in whole or in part without prior written permission of AzureWave.
1.3.4 Operating Conditions
Features
Description
Operating Conditions
Voltage
VBAT: 3.2 ~ 4.8V ; typical: 3.6V
VIO : 1.71 ~ 3.63V
Operating Temperature
-30 to +85
o
C
1
Operating Humidity
less than 85% R.H.
Storage Temperature
-40 to +100
o
C
Storage Humidity
less than 60% R.H.
ESD Protection
Human Body Model
1KV per JEDEC EID/JESD22-A114
Changed Device Model
250V per JEDEC EIA/JESD22-C101
1
Functionality is guaranteed across this ambient temperature range. Optimal RF performance specified in the data sheet,
however, is guaranteed only for -20
o
C to 75
o
C.