Data Sheet
Table Of Contents
24
3.7 Sleep Clock(Optional)
An external crystal is used for generating all radio frequencies and normal operation clocking. As an
alternative, an external frequency reference driven by a temperature-compensated crystal oscillator
(TCXO) signal may be used. No software settings are required to differentiate between the two. In
addition, a low-power oscillator (LPO) is provided for lower power mode timing.
External 32.768KHz Low-Power Oscillator
Symbol Parameter Min Typ Max Units
CLK
Clock frequency range/ accuracy
CMOS input clock signal type
±250 ppm (initial, aging, temperature)
-
32.768
-
kHz
PN Phase noise requirement (@ 100KHz)
-
-125
-
dBc/Hz
J
C
Cycle jitter
-
1.5
-
ns
(RMS)
SR Slew rate limit (10-90%)
-
-
100 ns
DC Duty cycle tolerance 20
-
80
%