Specifications

818 Sport Models
30
Problem/
Report
Possible Cause Suggested Action
Slow but Continuous Water Dispense
818 MODELS ONLY
Trouble Shooting Fault Diagnosis Guide 6
Miscellaneous
From Ambient
or Cold Water
Valve
Low incoming Water
pressure.
Consider re-plumbing to alternative supply
if possible.
From Sparkling
Water Valve
Low/no CO
2
Pressure. Fit Booster Pump Set.
Check Regulator and or replace cylinder.
Intermittent Water Dispense
From Ambient
or Cold Water
Valve
Trapped air in pipe work
(especially where water
pressure is low or after
filter change).
Hold button on to purge air out. (This could
take several minutes where pressure is low).
Pre-flush filters.
Button Not being pressed
enough.
Press button firmly N.B. This could be
caused by a surrounding cold environment
making the action stiffer.
Faulty PCB Replace PCB.
From Ambient
or Cold Water
Valve and
hammering
noise
Fluctuating mains water
pressure situation.
Contact Azure Technical Support regarding
special replacement washers available.
Continuous Water Dispense
From Ambient
or Cold Water
Valve
Button jammed on/faulty. Replace PCB and or/ button Panel as needed.
Debris blocking hole in
diaphragm washer.
Dismantle Valve and clean out.