Specifications

818 Sport Models
27
Problem/
Report
Possible Cause Suggested Action
Water Dispenses But Not Correct Temperature
818 MODELS ONLY
Trouble Shooting Fault Diagnosis Guide 3
Water Dispenses but Not Correct Temperature
Ambient Water
too warm (818
only)
Low usage and / or fed from
water supply pipe in warm
ducting.
Advise user replacing external causes and
solutions.
Cold water not
Cold
Cooling and or Sparkling
System switched off.
Check switch positions as necessary.
Compressor runs and
switching off (cool/warm to
touch )- Thermostat set too
high.
Decrease Cold Thermostat set point.
Faulty Thermostat. Replace Thermostat
Compressor runs but not
Switching off (Hot to touch).
See Appendix-Technical Advice to diagnose.
Refrigeration problem.
Compressor not running at
all.
Check and replace if necessary.
No electricity power supply. Check power cord connected and live, and
machine is switched on.
Compressor only hums
slightly/ briefly.
Check and replace relays.
Relays loose. Check and refit relays.
Compressor Faulty. See Appendix-Technical Advice to diagnose.