Installation guide

Quadro Manual II: Administrator's Guide Administrator's Menus
Quadro4x, 4xi, 4xa, 4xia, 4xs, 4xis, Quadro16x, 16xi, 16xa, 16xia, 16xs, 16xis; (SW Version 3.1.x) 20
selection enables Time Based and Weekday Based
checkboxes. Selecting one or both of them allows to define
the time and the weekday, when configuration check/update
will be automatically performed.
Fig. II-29: Upload Configuration page
Update Policy Selection manipulation radio-button group is used to select the operation performed on the selected:
Check only for update – with this option, system will only perform checking of the availability of new suitable configuration and will log
corresponding event in the
Events table (depending on configuration in Events Settings).
Check and update immediately - with this option, system will check the availability and correspondingly update the new configuration and will
log corresponding event in the Events table (depending on configuration in Events Settings).
Check and update immediately without any feedback - with this option, system will check the availability and correspondingly update the
new configuration but will not log any events on this.
Check now for new update functional button performs manual checking of the availability of new suitable configuration and logs corresponding
event in the Events table (depending on configuration in Events Settings).
Update now functional button performs manual checking and update of the availability new configuration and logs corresponding event in the Events
table (depending on configuration in Events Settings).
Update now without feedback functional button performs manual checking and update of the availability new configuration and does not log any
events on this.
Download current configuration in a legible format link refers to the Configuration Summary page where necessary configuration part or a
complete configuration can be defined and downloaded or viewed.
Configuration Summary page is used to define the necessary
configuration part and to download it to PC or to view it directly in
the browser.
In the text field on this page configuration part need to be
downloaded should be specified. Pressing Start generate a
legible configuration file will start parsing the configuration
structure of the device. Progress will be seen in the area below.
Cancel generation process button appears immediately
configuration generation procedure starts and is used to stop it.
Download generated configuration button becomes available
once legible configuration generation is over and is used to
download the generated file to the PC in the plain text format.
Necessary changed can be done in the downloaded
configuration file and then uploaded back to the system.
Fig. II-30: Configuration Summary page
Attention: Make sure the changes you have done in the downloaded legible configuration file are valid and will not corrupt the system when being
uploaded back to device.
View generated configuration button becomes available once legible configuration generation is over and is used to view the generated file directly
in the browser.Upload a legible configuration file link refers to the page where configuration file can be uploaded in text format. Browse button in
the opened page is used to browse the certain legible configuration file to be uploaded and updated to the system. Configuration files to be uploaded
should be in the *.txt format, otherwise system error occurs. Configuration file upload progress will be displayed in the area below.
Events
The Events page shows two tables and displays all system events that have occurred in one table and event settings in the other.
The System Events page may be accessed with Events link
from the main menu. It lists information about system events that
have occurred on Quadro. When a new event takes place a
record is added to the System Event table and for failure events
(priority 2 and 3, see below) additionally a warning “Please
check your pending events!” appears at the bottom of all
management pages.
The system events and the warning message are visible only for
the administrator. The warning link, (which leads directly to the
System Events page) will disappear from the management
pages if the administrator has marked all new events as read.