FMX-42 INSTRUCTIONS 4-CHANNEL PORTABLE MIXER Azden Corporation 147 New Hyde Park Road P.O. Box 10 Franklin Square, NY 11010 vox 516.328.7500 • fax 516.328.7506 azdenus@azdencorp.com • www.azdencorp.com Rev. 4 © Azden Corp.
12 5 20 1 13 11 8 7 6 <0.005% @ 1 kHz (@ LINE position +19 dBu output) 16 T.H.D. Balanced Output 4 -120 dBu (A weighted, Input Equivalent Level) 17 1400 g (without batteries) 49.3835 oz (without batteries) Weight Level Line Input Standard +4 dBu (electronically balanced) Maximum > +26 dBu (=4 dBu position) XLR 3-pin x 4 (CH1, 2, 3 and 4) 56H x 220W x 150.5D mm (without protrusions) 1.968H x 8.6614W x 5.9055D inches (without protrusions) 6 Alkaline “AA” Approx. 10 hours (Meter Illum.
OUTPUTS and SETTINGS Monitor “LEVEL” and “MONITOR” Output Jack: The “MONITOR” “LEVEL” (22) adjusts the volume of headphones connected to the “MONITOR” output jack (23). Zero is the lowest (quietest) setting, 10 is the highest (loudest). Monitor “SELECT”: Normally, the monitor “SELECT” switch (24) is set to position “L/R”. In this position you will monitor the sound of all connected microphones using stereo headphones.
“INPUT LEVEL” Settings: “+4”, “-30 dBu”, “-50 dBu” Each input channel of the FMX-42 has its own level setting (7). Select the input level that is best suited for the microphone, wireless receiver or line-level audio component that you are connecting to each input. The “+4” setting is for line-level audio, “30 dBu” and “-50 dBu” are both microphone-level settings. For the microphonelevel settings, start with the “-30 dBu” position.