where the antenna can come into contact with such circuits. When installing
antennas, take extreme care not to come into contact with such electrical circuits, as
they can cause serious injury or death.
Grounding Warning
Please always remember to protect your MST200 system by installation of
grounding lines. The ground connection must be complete before connecting power
to the MST200 enclosure. The requirement of grounding is to make sure the
resistance must be less than 5 ohm between the ground termination point to
grounding tier.
Power Installation Warning
The installation of power switch must be performed by a trained professional
technician.
The power switch is not supplied with the MST200. The power cord must be
assembled by a professional installer, and the final assembly must comply with
related requirements.
RF Device Protection
Before powering up MST200, RF port must be connected to valid load,
powering up with unloaded RF port is not allowed. Improper operation with power
can cause damage of RF module. Azalea will not take any responsibility for such
damage.