6 Grounding of MST200
The grounding of MST200 is to protect MST200 from electrostatic damage, there is
grounding terminal on the enclosure of MST200.
Tools needed: Paper knife, Pliers, Crimping Pliers, and Cross Screwdriver.
The procedure of grounding is as:
1 Put naked side of grounding wire into the copper ring, and press it firmly by
Crimping Pliers;
2 Unmount the screw of in the grounding terminal.
3 Put the copper ring into the grounding terminal.
4 Fasten the screw by Cross Screwdriver;
5 Connect the other side of grounding wire with grounding bar;
6 Daub butter on both side of grounding wire
Never skip grounding in the MST200 installation, and it must be finished
before powering up MST200.The residence of grounding wire must be less than 5
ohm.
Figure 13 Grounding of MST200