User's Manual
AZALEA MSR4000 INSTALLATION GUIDE
COPYRIGHT 2008 AZALEA NETWORKS
4
Grounding Warning
Please always remember to protect your MSR4000 system by installation of grounding
lines. The ground connection must be complete before connecting power to the MSR4000
enclosure. The requirement of grounding is to make sure the resistance must be less than 0.1
ohm between the ground termination point to grounding tier.
Power Installation Warning
The installation of power switch must be performed by a trained professional
technician.
The power switch is not supplied with the MSR4000. The power cord must be assembled by a
professional installer, and the final assembly must comply with related requirements.
Solar Irradiation and high Temperature Protection
Please pay attention of sunlight which will make the working temperature of MSR4000
higher then the specification
MR4000 would be located under sunlight. The solar shield which provided in Azalea standard
package should be installed to outdoor MSR4000. The Azalea Warrantee policy does not
cover those outdoor products which Solar shield is not installed for it. Please contact Azalea
technical support engineers for detail information.
RF Device Protection
Before powering up MSR4000, RF port must be connected to valid load, powering up
with unloaded RF port is not allowed. Improper operation with power can cause damage of RF
module. Azalea will not take any responsibility for such damage.