take extreme care not to come into contact with such electrical circuits, as they can cause
serious injury or death.
Grounding Warning
Please always remember to protect your MSR4000 system by installation of
grounding lines. The ground connection must be complete before connecting power to the
MSR4000 enclosure. The requirement of grounding is to make sure the resistance must be
less than 5 ohm between the ground termination point to grounding tier.
Power Installation Warning
The installation of power switch must be performed by a trained professional
technician.
The power switch is not supplied with the MSR4000. The power cord must be assembled
by a professional installer, and the final assembly must comply with related requirements.
Solar Irradiation and high Temperature Protection
Please pay attention of sunlight which will make the working temperature of
MSR4000 higher then the specification
MR4000 would be located under sunlight. The solar shield which provided in Azalea
standard package should be installed to outdoor MSR4000. The Azalea Warrantee policy
does not cover those outdoor products which Solar shield is not installed for it. Please
contact Azalea technical support engineers for detail information.
RF Device Protection
Before powering up MSR4000, RF port must be connected to valid load,
powering up with unloaded RF port is not allowed. Improper operation with power can
cause damage of RF module. Azalea will not take any responsibility for such damage.