Data Sheet
26
Here is the way to use the different wires (be careful the servomotor and the base are note using the same color
code.
For the wires connection, you must use a terminal block and proceed as follows:
Wires to connect with each other
Function
Thick brown (mast), thick brown (servomotor) , black (USB) , black (button led)
Ground (0V or GND)
Thick blue (mast), red (servomotor), red (USB), red (button led)
+5V
Thin yellow (mast), thin yellow (button)
+12V permanent
Thin red (mast), thin red (button)
+12V temporary
Thin green, thick orange (servo)
Data (servo command)
! Be careful not to confuse the 2 red wires coming from the button; one of them (5V) is used for the LED (the
external one) and the other (+12V) is used for the button relay (just near the yellow one)