Installation Manual Part 2
Company Proprietary
Adaptive Broadband
U-NII Product Installation Manual 05/29/2001
10-7
10.6 Cable Specifications
10.6.1 Outdoor Cable Specifications
The following Table 10-8 describes all the outdoor cable specifications.
Table 10-8 Outdoor Cable Specifications
Item Specification
Product type Twisted pair
Performance category CAT 5
Frequency 100 MHz
No. of pairs 4
Impedance 100 Ohms +/- 15 Ohms
Capacitance (nominal) 4.5 nF/100 meters
Attenuation EIA/TIA 568 CAT5
Near end cross talk EIA/TIA 568 CAT5
DC resistance/unbalanced < 10 Ohms/100 meters max.
Shielded Yes
Wire/cable type Solid
Wire size 24 AWG
Cable outer diameter (nominal) 0.232 inches
Jacket thickness (nominal) 0.030 inches
Cable jacket material Polyethylene, UV resistant
Conductor material Copper
Insulation material Solid polyolefin
Shield type BBDN or BBDG
Dielectric breakdown 2500 Volts DC conductor to conductor
Operating temperature range -40° C to +70° C
Installation temperature range 0° C to +60° C