Installation Manual Part 2
Company Proprietary
Adaptive Broadband
U-NII Product Installation Manual 05/29/2001
10-6
Figure 10-4 Powering SU through Junction Box
10.5.4 Power Consumption
Table 10-6 shows the power consumption of an SU, EX and AP.
Table 10-6 SU, EX and AP Power Consumption
Item Power Source Power Range Power Consumption
W (typical)
Subscriber Unit,
AB-Access
Extender and
Access Point Unit
48 VDC 38 to 72 VDC including
fluctuations
14
10.5.5 Distance Limitations
The SU uses shielded outdoor rated CAT5 cable between the installed unit and the indoor
junction box. For the unit to receive acceptable voltage to operate, this cable is limited to 60
meters. Between the junction box and the customer premises PC (or hub, Ethernet Switch,
Router, etc.), the system uses standard indoor CAT5 cable, which is rated for a maximum
functional distance of 100 meters when running the Ethernet 10BaseT interface. For an AP (or
SU) connected via ATM25, the distance limitation of the data signaling is 270 meters.
10.5.6 Physical Specifications
Table 10-7 provides the weight and dimensions of an SU.
Table 10-7 SU Weight and Size
Item Weight Dimension
Subscriber unit 7.8 lb. (3.5 kg) 13W x 13H x 3D in.
(32W x 32H x 8D cm)