6.6.2.4 Mark the AB-Access Extender Cables
Attention!
Step 1 is important, and will enable the network installer to configure the
system easily.
2. Mark the cable with a permanent label and make a note so that the network installer knows
which outdoor EX transceiver is connected to which port on the Access Panel junction box.
6.6.3 Grounding The System
The AB-Access System must be properly grounded in order to protect it and the structure it is
installed on from lightning damage. This requires:
8. Grounding all the outdoor transceivers as shown in Figure 6-14.
9. Grounding the Access Panel to the rack.
6.6.3.1 Grounding the Outdoor AB-Access Extender
8. Place the grounding rod so as to allow for the shortest possible path from the grounding
cable to the outdoor AB-Access Extender.
9. Drive the grounding rod into the ground at least eight inches from the ground surface.
10. Attach a grounding clamp to the grounding rod. You will use this clamp to attach grounding
wires for both the outdoor transceiver and indoor junction box, reference Figure 6-16.
Figure 6-15 Ground Connections to AB-Access Extender Transceiver