Installation Manual Part 1

Company Proprietary
Adaptive Broadband
U-NII Product Installation Manual 05/29/2001
6-8
TBD: Update this section for AB-Access Extender – insert graphic of underside of Extender
showing cable routing
NOTE: The Grommet is made of a special conductive material used to complete
the ground between the AB-Access Extender and Access Panel.
4. Insert the cable end through the grommet clamping plate (Figure 6-11)
5. Insert the cable end through the grommet. The tapered end of the grommet should be
opposite the cable end.
6. Strip 1 inch of insulation off the cable end. Leave 3/8 inch of shielding showing and trim the
wire ends flat ½ inch from there.
7. Using a piece of 1 inch squared tinned copper foil, wrap the foil around the shield/braid and
sheath with the left edge aligned with the edge of the braid, as shown in the following
Figures 6-12 and 6-13.