Installation Manual Part 1
Company Proprietary
Adaptive Broadband
U-NII Product Installation Manual 05/29/2001
5-13
Attention! The grounding wire should be long enough to reach from the mounting pole
to the grounding rod with 3 to 6 extra feet allowed for strain relief.
4. Connect a ground lug to one end of the grounding wire.
5. Remove one of the lower mounting screws of the mounting pole. Insert a screw through the
grounding lug terminal and re-install it to the mounting pole.
6. Attach the grounding wire to the clamp on the grounding rod, reference Figure 5-17.
If necessary, use wire staples to secure the grounding wire to the outside wall.
Figure 5-17 Mounting Pole with Ground Lug
7. Install a grounding wire from the junction box to the grounding rod.
Ground lug
with #10 awg
copper wire