Installation Manual Part 1
Company Proprietary
Adaptive Broadband
U-NII Product Installation Manual 05/29/2001
5-4
5.5.1 Overview
Following are the installation steps you will perform:
1. Install the mounting poles.
2. Mount the outdoor transceivers.
3. Mount the access panel.
4. Ground the outdoor transceivers and access panel
5. Connect the interconnect cables.
5.5.2 Installing The Mounting Poles
First install the mounting poles, on which you will mount the outdoor transceivers.
Bear in mind the direction in which the transceivers will point.
Attention!
The mounting pole must be mounted in a vertical position. Failure to do
so may result in improper alignment of the outdoor transceiver.
If you need to tilt the transceiver down to avoid self-interference in a
cellular-style deployment, you should use an (optional) tilt bracket.
Warning! The mounting pole must be grounded. See
Grounding The System
in
Section 5.6.3.
5.5.3 Installing On An Antenna Mast
1. Position the mounting pole on the antenna mast.
2. Insert the U-bolts around the mast and through the holes in the mounting pole. Install a
washer and nut to each side of the threaded U-bolt and hand tighten. Repeat this step for the
second U-bolt.
3. Tighten nuts equally until mounting pole is secure and cannot rotate.
Figure 5-4 Mounting Pole Installed on Pole or Antenna Mast
Typical 2 ½ inch