Installation Manual

Table Of Contents
ABMAX ACCESS POINT INSTALLATION AND MAINTENANCE GUIDE VERSION 1.1
21
OF 39
6.3 Install the Interconnect Cables (Transceiver End)
1) Remove the grommet and clamping plate from the outdoor transceiver by removing the two
screws.
Figure 6-1: Grommet Location - Underside of Access Point
Note: The Grommet is made of a special conductive material used to complete the ground
between the Access Point and wallbox.
2) Insert the cable end through the grommet clamping plate (Figure 6-1:)
3) Insert the cable end through the grommet. The tapered end of the grommet should be
opposite the cable end.
4) Strip 1/2 inch of insulation off the cable end. Trim the wire ends flat as shown in Figure 6-2.
Figure 6-2 Outdoor Transceiver End of the Interconnect Cable with Cable Preparation