4.1.6 Power Settings for Operation in the 3.650 - 3.675 GHz Band
AP Antenna Gain
..........
16.5 dBi External, Sectored, 60deg
1 dBi .......... Cable Loss
Channel Spacing: 7MHz
Freq Gant BW TX set PPSD
(cond)
PPSD
EIRP
PPSD
EIRP Limit
Margin
(MHz) (dBi) (MHz) (dBm) (dBm/MHz) (dBm/MHz) (dBm/MHz) dB
3662.5 15.5 7 10 14.45 29.95 30 0.05
Channel Spacing: 3.5MHz
Freq Gant BW TX set PPSD
(cond)
PPSD
EIRP
PPSD
EIRP Limit
Margin
(MHz) (dBi) (MHz) (dBm) (dBm/MHz) (dBm/MHz) (dBm/MHz) dB
3662.5 15.5 3.5 8 14.49 29.99 30 0.01
AP Antenna Gain
14 dBi External, Sectored, 90deg
1 dBi Cable Loss
Channel Spacing: 7MHz
Freq Gant BW TX set PPSD
(cond)
PPSD
EIRP
PPSD
EIRP Limit
Margin
(MHz) (dBi) (MHz) (dBm) (dBm/MHz) (dBm/MHz) (dBm/MHz) dB
3662.5 13 7 12 16.95 29.95 30 0.05
Channel Spacing: 3.5MHz
Freq Gant BW TX set PPSD
(cond)
PPSD
EIRP
PPSD
EIRP Limit
Margin
(MHz) (dBi) (MHz) (dBm) (dBm/MHz) (dBm/MHz) (dBm/MHz) dB
3662.5 13 3.5 10 16.97 29.97 30 0.03