3.9.2.2 Completing the Connection of the DC Power Supply/NIA
1) In
sert one end of an RJ-45 to RJ-45 Ethernet cable assembly to the RJ-45 receptacle, labeled
Data, on the outside of the DC PSU/NIA and the other end to the customer's computer (Figure
3-24:).
Figure 3-24: Connect customer computer or network device
2) Check to see that the connection to the Access Point is in place.
Warning
It is extremely important to connect the DC power to the DC PSU/NIA as the last
step. Connecting DC power prematurely can damage the Access Point and lead to
faulty behavior.
Note
The DC PSU/NIA does not come with cables or
power cord. Service provider must
provide their own cables and power cord.
Note
Custome
r equipment requiring Ethernet connectivity may not be located more than
100 m (328 ft.) from the Access Point.