User's Manual

Table Of Contents
EXCELMAX ACCESS POINT CELL INSTALLATION AND MAINTENANCE GUIDE VERSION 1.4
41
OF 65
3.9.1 AC PSU/NIA Option
3.9.1.1 Connecting the Access Point to the AC Power Supply/NIA
The following procedures will guide you through the connection of the AC PSU/NIA unit:
1) Rem
ove the new AC PSU/NIA from the installation kit.
2) Using a shielded RJ-45 plug, terminate (attach plug) to the Access Point Cat-5 cable per the
manufacturer's recommended specifications for plug attachment. (Recommended
manufacturer: AMP P/N 5-569552).
3) Insert the RJ-45 plug from the outdoor Access Point into the RJ-45 receptacle, labeled
Data+Power, on the NIA (Figure 3-18:).
Figure 3-18: Connect the Access Point
Warning
It is extremely important to connect the AC power t
o the AC PSU/NIA as the last
step. Connecting AC power prematurely can damage the Access Point and lead to
faulty behavior.