3.8.4 Attaching the Ground Wire (recommended)
Figure 3-16: Attaching the Ground Wire
1) Crimp one end of 2.8 mm (8 AWG) wire to the ground lug.
2) Attach the assembled ground lug to the transceiver housing using an M6 x 16 lg hex bolt, M6
split lock washer and M6 flat washer. Torque the hex bolt to 8.8 ± .7 Nm (78 ± 6 in.-lb.) using a
10 mm open-end wrench.
3) Attach the remaining ground wire end to the "Earth Ground" and/or mounting pole per the local
electrical code.
Warning
Axxcelera recommends grounding the unit and supplies the following instructions
as a reference only. Necessary grounding should be completed per local electrical
codes.
M6 Hex Bolt
Mounting Pole
M6 Lock Washer
M6 Flat Washer
8 AWG )
Ø2.8 mm(
Ground Wire (not provided)
To Earth Ground
Access Point
Ground Lug