EXCELMAX ACCESS POINT CELL INSTALLATION AND MAINTENANCE GUIDE VERSION 1.4
37
OF 65
3.8.4 Attaching the Ground Wire (recommended)
Figure 3-16: Attaching the Ground Wire
1) Crimp one end of ∅ 2.8 mm (8 AWG) wire to the ground lug.
2) Attach the assembled ground lug to the transceiver housing using an M6 x 16 lg hex bolt, M6
split lock washer and M6 flat washer. Torque the hex bolt to 8.8 ± .7 Nm (78 ± 6 in.-lb.) using a
10 mm open-end wrench.
3) Attach the remaining ground wire end to the "Earth Ground" and/or mounting pole per the local
electrical code.
Warning
Axxcelera recommends grounding the unit and supplies the following instructions
as a reference only. Necessary grounding should be completed per local electrical
codes.
M6 Hex Bolt
Mounting Pole
M6 Lock Washer
M6 Flat Washer
8 AWG )
Ø2.8 mm(
Ground Wire (not provided)
To Earth Ground
Access Point
Ground Lug