The strap is then connected to the tower. The clamp is wound with waterproof tape.
3.7.5 Waterproofing Cable Connections
Wrap RF cable connections with waterproof tape.
3.8 Installing the Access Point
3.8.1 Mounting L-bracket to the Access Point
Figure 3-13: Mounting the L-bracket to the Access Point
1) Attach the L-bracket to the Access Point using 4 hex bolts with 4 split lock washers.
2) Torque the hex bolts to 8.81 ±67 Nm (78 ±6 in.-lb.) with a 10 mm open-end wrench.
M6 X 16 mm Hex Bolt
4 ea
M6 Split Lock Washer
4 ea