User's Manual
Table Of Contents
- 1.0 Preface
- 2.0 Introduction
- 3.0 Installation
- 3.1 Compliance Alert - Operation in the 3.4 - 3.6 GHz Band
- 3.2 Operation in the 3.650 - 3.675 GHz Band
- 3.3 Installation Warnings
- 3.4 Environmental Cautions
- 3.5 Installing Outdoor Equipment
- 3.6 Installing an Optional Sector Antenna
- 3.7 Installing Optional Omnidirectional Antenna
- 3.8 Installing the Access Point
- 3.9 Power and Data Connections - AC and DC Power Options
- 4.0 Configuring an Access Point for Single-Channel Use
- 5.0 Maintenance Guide
- Appendix A: NIA/Power Adapter Specifications: Model # TR60A-POE-L
- Appendix B: ExcelMax DC PSU/NIA (020-44109-0802)
- Appendix C: Glossary of Terms and Abbreviations
EXCELMAX ACCESS POINT CELL INSTALLATION AND MAINTENANCE GUIDE VERSION 1.4
12
OF 65
2.2.1.1 OPTIONAL: GPS Synchronization
Global Positioning System (GPS) support is a factory-fit option for ExcelMAX Access Points.
When supported, a GPS antenna may be connected to each co-located ExcelMAX Access Point
to allow them to synchronize their RF transmissions. Although not required for basic system
operation, use of the “network synchronization” feature synchronizes Access Points so that they
transmit and receive at the same time to limit interference. This function of the GPS reduces
adjacent channel interference, and also reduces interference between adjacent base-station sites
(i.e., frequency re-use).
2.3 Major Components
2.3.1 Indoor Equipment
The indoor equipment consists of the NIA/Power Adapter, which may be an AC or DC variant,
according to the model ordered.
2.3.1.1 AC NIA/Power Adapter
The AC NIA/Power Adapter (Figure 2-4:) is the customer's interface with the Access Point. The AC
NIA/Power Adapter contains interfaces to the AC power supply, customer's data network, and the
Access Point connecting cable. The AC NIA/Power Adapter has a power indicator LED that
illuminates when power is applied to the AC NIA/Power Adapter. The AC NIA/Power Adapter is
wall-mountable using the screw hangers on the back. An included tie wrap is used for strain relief
of the interconnecting cable.
Figure 2-4: AC NIA/Power Adapter