Figure 6-11 Interconnect Cable Installation to Subscriber Unit -- Bottom View
6.5.4 Connecting to the Indoor Junction Box
Note that the junction box should still be disassembled and not screwed to the wall at this point.
11. Strip 2 inches of insulation off the junction box end of the interconnect cable.
Attention! Don’t cut off the shield from the cable – you will need it to ground the system
later.
12. Insert the cable end through the notched out section of the junction box.
13. Reinstall the PCB into the junction box using the two screws, allowing enough of the
interconnect cable to be able to reach the punch down block and wrap around the mounts of
the cover plate for strain relief.
14. Using Figure 6-12 as a guide, use the 110 punch down tool to punch down each wire into the
slot on the punch down block.
Figure 6-12 Interconnect Cable Connections to Indoor Junction Box