Install Manual
Table Of Contents
- Preface
- PLEASE READ THESE SAFETY PRECAUTIONS!
- Table of Contents
- List of Figures
- List of Tables
- AB-Access Product Overview
- Getting Started
- Base Station Installation
- Access Point Installation
- AB-Extender Installation
- Subscriber Unit Installation
- Indoor Junction Box
- Glossary
- Acronyms/Abbreviations
Axxcelera Broadband Product Install Manual Page 57 of 71
NOTE: The Grommet is made of a special conductive material used to complete the
ground between the Subscriber Unit and indoor junction box.
Figure 6-9 Grommet Location -- Underside of Subscriber Unit
2. Insert the cable end through the grommet clamping plate (Figure 6-10).
3. Insert the cable end through the grommet. The tapered end of the grommet should be
opposite the cable end.
4. Strip 1 inch of insulation off the cable end. Leave 3/8 inch of shielding showing, and trim
the wire ends flat ½ inch from there.
5. Using a piece of 1inch squared tinned copper foil, wrap the foil around the shield/braid and
sheath with the left edge aligned with the edge of the braid, as shown in the following Figure
6-10.
Grommet
Grommet
clamping
plate
Note direction
of taper
Insert wire
into channels
1/2"
3/8"
Shielding
Pin 1
Tab on
underside
1" square tinned copper foil - wrap the copper foil around the
shield/braid and sheath with the left
edge aligned with the edge of the braid.
Figure 6-10 Outdoor Subscriber Unit of the Interconnect Cable with Cable Preparation
6. Separate the twisted pair wires and align by color code in the order listed in the following
Table 6-7.
Grommet is
conductive
and used to
complete
the ground