Install Manual

Table Of Contents
Axxcelera Broadband Product Install Manual Page 48 of 71
Figure 5-14 Mounting Pole with Ground Lug
7. Install a grounding wire from the junction box to the grounding rod.
5.6.2 Grounding the Indoor Junction Box
To ground the indoor junction box, you will need to install a grounding wire from the junction
box to the grounding rod. The wire should be long enough to reach from the junction box to the
grounding rod with 3 to 6 extra feet to allow for strain relief.
9. Feed the grounding cable through the broken out section of the wall cover (alongside the
interconnect cable).
10. Connect a ground lug to the grounding cable by crimping the lug to the wire, as shown in
Figure 5-15.
11. Remove the hex nut on the grounding post, as shown in Figure 5-15.
12. Install the grounding lug terminal onto the grounding post.
13. Attach the wire shield of the interconnect cable to the ground post. You may need to crimp
or solder an extra length of wire to the shield in order to attach it to the grounding post.
14. Re-install the hex nut to the grounding post and tighten.
15. Attach the grounding wire to the clamp on the grounding rod.
16. Use the provided small wire tie to firmly attach the interconnect cable to the ground lug.
This will provide strain relief for the cable and prevent the data and power leads from being
disturbed during installation.