Install Manual

Table Of Contents
Axxcelera Broadband Product Install Manual Page 33 of 71
3. Reinstall the PCB into the junction box using the two screws, allowing enough of the
interconnect cable to be able to reach the punch down block and wrap around the mounts of
the cover plate for strain relief.
4. Using Figure 4-13 as a guide, use the 110 punch down tool to punch down each wire into the
slot on the punch down block.
Figure 4-13 Interconnect Cable Connections to Indoor Junction Box
5. Snip off excess wire ends, if necessary.
Attention! Avoid excessive wire loops when connecting the wire to the punch down block.
For now, set the junction box to one side leaving it disassembled. You will reassemble it and
mount it on the wall when you have grounded the system.
4.5.2.4 Mark the Access Point Cables
Attention! Step 1 is important, and will enable the network installer to configure the
system easily.
1. Mark the cable with a permanent label and make a note so that the network installer knows
which outdoor AP transceiver is connected to which port on the Access Panel junction box.
4.6 Grounding the System
The AB-Access System must be properly grounded in order to protect it and the structure it is
installed on from lightning damage. This requires: