Service manual
SERVICE MANUAL TNC 415B/425
Page 29
Issue: 20.08.95
6.2.2 Pin Layout: PL 400
X1
Pin No.
Assignment
as 1. PL as 2. PL
X4
Pin No.
Assignment
as 1. PL as 2. PL
1 O32 064 1 I126 I254
2 O33 065 2 I74 I202
3 O34 066 3 I73 I201
4 O35 067 4 I72 I200
5 O36 068 5 I71 I199
6 O37 069 6 I70 I198
7 O38 070 7 I69 I197
8 O39 071 8 I68 I196
9 O40 072 9 I67 I195
10 O41 073 10 I66 I194
11 O42 074 11 I65 I193
12 do not assign 12 I64 I192
X2
Pin No.
Assignment
as 1. PL as 2. PL
X5
Pin No.
Assignment
as 1. PL as 2. PL
1 O43 075 1 I86 I214
2 O44 076 2 I85 I213
3 O45 077 3 I84 I212
4 O46 078 4 I83 I211
5 O47 079 5 I82 I210
6 O48 080 6 I81 I209
7 O49 081 7 I80 I208
8 O50 082 8 I79 I207
9 O51 083 9 I78 I206
10 O52 084 10 I77 I205
11 O53 085 11 I76 I204
12 do not assign 12 I75 I203
X3
Pin No.
Assignment
as 1. PL as 2. PL
X6
Pin No.
Assignment
as 1. PL as 2. PL
1 O54 086 1 I98 I227
2 O55 087 2 I97 I226
3 O56
1)
088
1)
3 I96 I225
4 O57
1)
089
1)
4 I95 I224
5 O58
1)
090
1)
5 I94 I223
6 O59
1)
091
1)
6 I93 I221
7 O60
1)
092
1)
7 I93 I220
8 O61
1)
093
1)
8 I91 I219
9 O62
1)
094
1)
9 I90 I218
10 control ready for operation 10 I89 I217
11 do not assign 11 I88 I216
12 +24V cannot be switched off 12 I87 I215
via ext. EMERG. STOP
1)
outputs cannot be switched off via ext. EMERG. STOP