Service manual

Function MP
No.
Bit
ABC
Input AE-6
Entry value
Feed rate and spindle override
Feed rate override, if rapid traverse
button pressed in "program run"
reserved
Feed rate override, if
rapid traverse button pressed in
"manual" or
rapid traverse button and handwheel
direction key pressed in "handwheel"
Override characteristic curve
7620
0
1
2
3

+ 0 = feed rate override inactive
+ 1 = feed rate override active
+ 0 = feed rate override inactive
+ 4 = feed rate override active
+ 0 = feed rate and spindle override in 1% increm.
+ 8 = feed rate and spindle override in 0.01% increm.,
and non-linear characteristic curve
% 1101
R H
1.0 TNC
415B/425
Machine Parameters MP 7620 08.05.95 5.2 69