Service manual
Display and Programming
Function MP
No. Bit
A B C Input AE-6
Entry value
Programming station 7210*
0 = control
1 = programming station: PLC active
2 = programming station: PLC inactive
0
POWER INTERRUPTED 7212
0 = press [CE] to confirm the message
1 = message is confirmed automatically
1
Block number increment size
(for ISO programming)
7220*
0 to 250
0 = no generation
0
Maximum length of file names
when opening a file
7222*
I02
0 = max. 8 characters
1 = max. 12 characters
2 = max. 16 characters
Disabling file types
(for selection, table of contents and ext.
data transfer)
7224.0*
0 = no file type disabled % 00000000
HEIDENHAIN programs (.H)0
+ 1 = disabled
ISO programs (.I)1
+ 2 = disabled
Tool tables (.T)2
+ 4 = disabled
Datum tables (.D)3
+ 8 = disabled
Pallet tables (.P)4
+16 = disabled
ASCII (text) files (.A)5
+32 = disabled
PLC help files (.HLP)608
+64 = disabled
Measuring point tables (.PNT)708
+128 = disabled
* accessible via code number 123
R H
1.0 TNC
415B/425/426