Service manual

3D-Touch Probe (General Parameters)
Function MP
No. Bit
A B C Input AE-6
Entry value
Selection of touch trigger probe 6010*

0 = transmission via cable (TS 120)
1 = infrared transmission (TS 510)
0
Probing feed rate 6120*

10 to 3 000 [mm/min] 80
Maximum measuring range 6130*

0.001 to 99 999.9999 [mm] 1
Safety clearance over measure-
ment point for automatic
measurement
6140*

0.001 to 99 999.9999 [mm] 1
Rapid traverse for probe cycle 6150*

10 to 10 000 [mm/min] 2000
M-function for 180° spindle
rotation to compensate the center
misalignment of the stylus
6160*

0 = function inactive
1 to 88 = number of M-function for probing
0
-04
1 = oriented spindle stop via NC
0 = function inactive
+1 to 88 = number of M function for oriented spindle
stop via PLC
0
Connection of Measuring Touch Probe or Touch Trigger Probe
Function MP
No. Bit
A B C Input AE-6
Entry value
Selecting the touch probe
(probing and digitizing cycles)
6200 * 10
0 = touch trigger probe
1 = measuring touch probe
0
* accessible via code number 123
R H
1.0 TNC
415B/425
Machine Parameters MP 6010 - MP 6200 08.05.95 5.2 44