Service manual

Function MP
No. Bit
A B C Input AE-6
Entry value
ASCII character for input
identification
EXT1
EXT2
EXT3 (PLC)
(E) 5203.0*
5203.1*
5203.2*
I02
I02
I02
0 to 127
0
0
0
ASCII character for file type
(for data output)
EXT1
EXT2
EXT3 (PLC)
5204.0*
5204.1*
5204.2*
I02
I02
I02
0 to 127
0
0
0
ASCII character for output
identification
EXT1
EXT2
EXT3 (PLC)
(A)
5205.0*
5205.1*
5205.2*
I02
I02
I02
0 to 127
0
0
0
ASCII character for beginning of
command block
EXT1
EXT2
EXT3 (PLC)
(SOH) 5206.0*
5206.1*
5206.2*
I02
I02
I02
0 to 127
0
0
0
ASCII character for end of
command block
EXT1
EXT2
EXT3 (PLC)
(ETB) 5207.0*
5207.1*
5207.2*
I02
I02
I02
0 to 127
0
0
0
* accessible via code number 123
R H
1.0 TNC
415B/425/426
Machine Parameters MP 5203.0 - MP 5207.2 03.01.95 5.2 42