Service manual
Adaptation of the Data Interface
Function MP
No. Bit
A B C Input AE-6
Entry value
Inhibiting a data interface
5000
0 = no interface inhibited
1 = RS-232 inhibited
2 = RS-422 inhibited
0
Data format and transfer stop
operating mode
EXT1
operating mode
EXT2
operating mode
EXT3 (PLC)
5020.0*
5020.1*
5020.2*
0 to 255 168
168
168
7 or 8 data bits 0
+0
= 7 data bits, bit 8 = parity
+1 = 8 data bits, bit 8 = 0, bit 9 = parity
Block check character 1
+0
= BCC character optional
+2 = control character not BCC
Transmission stop through RTS 2
+0
= inactive
+4 = active
Transmission stop through DC3 3 +0 = inactive
+8
= active
Character parity even/odd 4
+0
= even
+16 = odd
Character parity on/off 5 +0 = off
+32
=on
Number of stop bits 6
+ 64
→
bit 6 = 1
7
+128
→
bit 7 = 1
bit 6 bit 7
0 1 = 1½ stop bits
1 0 = 2 stop bits
0 1 = 1 stop bit
1 1 = 1 stop bit
* accessible via code number 123
R H
1.0 TNC
415B/425/426
Machine Parameters MP 5000 - MP 5020.2 03.01.95 5.2 40