Service manual

Integral PLC
Function MP
No. Bit
A B C Input AE-6
Entry value
PLC program from RAM or from
EPROM
4010

-
+ 0 = EPROM operation
+ 1 = RAM operation 0
PLC compatibility to TNC 415/425
convert axis words W1024ff to markers
convert new markers into old markers
convert configuration bits from MP4210
into markers
error markers are available
non-volatile markers in the range
M1000 to M1999
4020
0
1
2
3
4
--
0 to 31
corresponding bit = 0
function inactive
corresponding bit = 1
function active
%00000
Automatic lubrication
X
Y
Z
IV
V
4060.0
4060.1
4060.2
4060.3
4060.4
0 to 65 535
[
65 536 µm
]
100
200
300
400
0
Maximum change of the temperature
compensation per PLC scan in the
PLC words W576 - W584
4070

0.0001 to 0.005 [mm] 0.0001
R H
1.0 TNC
415B/425/426
Machine Parameters MP 4010 - MP 4070 03.01.95 5.2 33