Service manual
Function MP
No. Bit
A B C Input AE-6
Entry value
Transient response of the spindle:
•
Spindle ON/OFF, M03, M04, M05;
•
Oriented spindle stop
•
"Tapping" cycle
•
"Rigid Tapping" cycle
3415.0
3415.1
3415.2
3415.3
-
-
-
-
-
-
-
-
0 to 1000[ms]
1
1
1
1
Positioning window for the spindle
3420
0 to 65 535 [increments] 10
Spindle pre-set
3430
0 to 360 [°] 0
Kv factor for the spindle
(per gear range)
gear range
gear range
gear range
gear range
gear range
gear range
gear range
gear range
1
2
3
4
5
6
7
8
3440.0
3440.1
3440.2
3440.3
3440.4
3440.5
3440.6
3440.7
0.1 to 10 1
1
1
1
1
1
1
1
R H
1.0 TNC
415B/425/426
Machine Parameters MP 3415.0 - MP 3440.7 03.01.95 5.2 31