Service manual

Function MP
No. Bit
A B C Input AE-6
Entry value
Controlled range for S-analogue output
Min. S-analogue voltage that can be output
Jog voltage for gear switching
(markers for direction of rotation: M2490/M2491)
3240.1
3240.2
0 to 9.999 [V]
0 to 9.999 [V]
0
0.1
Controlled range for S-speed output
(TNC 426 PA)
Min. motor speed that can be output
Motor speed for gear switching (markers for
direction of rotation: M2490/M2491)
3240.1
3240.2
-
-
-
-
0 to 9.999 [1000/min]
0 to 9.999 [1000/min]
0
0.1
Limit with S-override
max.
min.
3310.0
3310.1
0 to 150 [%] 150
0
Ramp gradient of the spindle:
Spindle ON/OFF, M03, M04, M05;
Oriented spindle stop
"Tapping" cycle
Tapping without floating tap holder
(Rigid Tapping)
3410.0
3410.1
3410.2
3410.3
0 to 1.999 [V/ms]
0.1
0.1
0.1
0.1
Ramp gradient of the spindle:
(TNC 426 PA)
Spindle ON/OFF, M03, M04, M05;
Oriented spindle stop
"Tapping" cycle
Tapping without floating tap holder
(Rigid Tapping)
3410.0
3410.1
3410.2
3410.3
-
-
-
-
-
-
-
-
0 to 1.999 [
1000 / min
ms
]
0.1
0.1
0.1
0.1
R H
1.0 TNC
415B/425/426
Machine Parameters MP 3240.1 - 3410.3 06.03.95 5.2 30