Service manual
Function MP
No. Bit
A B C Input AE-6
Entry value
Axis halt on TOOL CALL with only a
spindle speed output
3030
0 = axis halt
1 = no axis halt
0
Programming the spindle speed
S = 0
(if MP3240.1
≠
0)
3120
0
⇒
S = 0 permitted
1
⇒
S = 0 not permitted
0
Polarity
•
of S-analogue voltage
(TNC 415B/425/426CA)
•
of nominal spindle speed
(TNC 426 PA)
3130
0 = M03: positive
M04: negative
1 = M03: negative
M04: positive
2 = M03 and M04: positive
3 = M03 and M04: negative
0
Count direction of the spindle
encoder
3140
0 = positive
1 = negative
0
Line count of the spindle encoder
3142 -
-
0 = 1024 lines
1 = 2048 lines
0
S-analogue voltage with
nominal speed
gear range
gear range
gear range
gear range
gear range
gear range
gear range
gear range
1
2
3
4
5
6
7
8
3210.0
3210.1
3210.2
3210.3
3210.4
3210.5
3210.6
3210.7
0 to 9.999 [V] 9
9
9
9
9
9
9
9
Revolutions of the motor with
nominal speed
(TNC 426 PA) gear range
gear range
gear range
gear range
gear range
gear range
gear range
gear range
1
2
3
4
5
6
7
8
3210.0
3210.1
3210.2
3210.3
3210.4
3210.5
3210.6
3210.7
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0 to 9.999 [1000/min]
9
9
9
9
9
9
9
9
R H
1.0 TNC
415B/425/426
Machine Parameters MP 3030 - 3210.7 06.03.95 5.2 29