Service manual
Spindle
Function MP
No. Bit
A B C Input AE-6
Entry value
Output of the spindle speed
3010
0 = spindle speed not output
6
coded
1 = only if speed changes
2 = with every TOOL CALL
analogue
3 = gear switching signal only if gear range
changes
4 = gear switching signal with every
TOOL CALL
5 = no gear switching signal
controlled spindle for orientation 6 = gear switching signal only if gear range
changes
7 = gear switching signal with every
TOOL CALL
8 = no gear switching signal
Output of an analogue voltage at
the analogue output of the spindle
(only if MP3010 < 3)
3011
-
0 = no function
1 = voltage is proportional to the current feed
rate
2 = voltage defined via PLC (module 9130)
3 = voltage defined via M-function
(M200 - M204)
0
Feed rate that corresponds to an
analogue voltage of 10V
(only if MP3011 = 1)
3012
0 to 300 000 [mm/min] 0
R H
1.0 TNC
415B/425/426