Service manual

Table 1: Entry values depending on the power stage
The following SIEMENS power stages can be connected to TNC 426 PA:
6SN1123-1AA00 6SN1123-1AB00
0AA0 0BA0 0CA0 0DA0 0EA0 0FA0 0AA0 0BA0 0CA0
VSA HSA VSA HSA VSA HSA VSA HSA
MP2110 14.14 25.45 50.91 50.91 79.2 79.2 158.4 158.4 198 198 14.14 25.45 50.91
MP2120 7.07 12.72 25.45 33.94 39.6 42.42 79.2 84.85 99 120.2 7.07 12.72 25.45
When using non-SIEMENS power stages, please contact HEIDENHAIN.
Table 2: Entry values depending on the motor
The following SIEMENS drives can be connected to TNC 426 PA:
1FT6064
6AC71
1FT6084
8AC71
1FT6086
8AC71
1FT6062
6AH71
1FT6082
8AH71
1PH6103
4NG4
1PH6107
4NG4
MP2200 0000011
MP2210 2 000 2 000 2 000 4 500 4 500 2 000 2 000
MP2220 2 915 3 080 2 970 6 435 6 930 9 900 9 900
MP2230 3443422
MP2280 0000014.022.1
MP2290 00000162189
MP2300 5.4 11.8 15.4 5.5 11.5 28.3 43.8
MP2310 21.5 46.95 61.7 22.06 62.2 45.3 70.1
When using non-SIEMENS drives, please contact HEIDENHAIN.
R H Tables for
1.0 TNC
415B/425/426