Service manual
Function MP
No. Bit
A B C Input AE-6
Entry value
Reference mark evaluation
Direction for traversing the reference marks X
Y
Z
IV
V
1320
0
1
2
3
4
0 = positive
+1 = X axis negative
+2 = Y axis negative
+4 = Z axis negative
+8 = IV. axis negative
+16 = V. axis negative
% 00000
Feed rate for traversing the reference marks
X
Y
Z
IV
V
1330.0
1330.1
1330.2
1330.3
1330.4
linear axis:
10 to 30 000 [mm/min]
rotary axis:
10 to 30 000 [°/min]
10 000
"
"
"
"
Feed rate for leaving the reference end-
position
(only if MP1350 = 2)
X
Y
Z
IV
V
1331.0
1331.1
1331.2
1331.3
1331.4
linear axis:
10 to 500 [mm/min]
rotary axis:
10 to 500 [°/min]
200
"
"
"
"
Axis sequence for reference mark traverse
1. axis
2. axis
3. axis
4. axis
5. axis
1340.0
1340.1
1340.2
1340.3
1340.4
0 = no ref. mark traverse
1 = X
2 = Y
3 = Z
4 = IV
5 = V
1
2
3
4
5
Type of reference mark approach X
Y
Z
IV
V
1350.0
1350.1
1350.2
1350.3
1350.4
0 = position encoder with distance-coded
reference marks (1. mode)
1 = position encoder without distance-coded
reference marks
2 = special function (linear measurement
with rotary encoder)
3 = position encoder with distance-coded
reference marks (2. mode)
1
1
1
1
1
R H
1.0 TNC
415B/425
Machine Parameters MP 1320 - MP 1350.4 03.01.95 5.2 12