Service manual
Function MP
No. Bit
A B C Input AE-6
Entry value
Software limit switch ranges
Range 1
Default setting after power-on:
Activation by PLC:
M2817 = 0, M2816 = 0
strobe marker M2824
X+
Y+
Z+
IV+
V+
X-
Y-
Z-
IV-
V-
910.0
910.1
910.2
910.3
910.4
920.0
920.1
920.2
920.3
920.4
linear axis:
-99 999.9999 to +99 999.9999 [mm]
rotary axis:
-99 999.9999 to +99 999.9999 [°]
+99 999.9999
"
"
"
"
-99 999.9999
"
"
"
"
Range 2
Activation by PLC:
M2817 = 0, M2816 = 1
strobe marker M2824
X+
Y+
Z+
IV+
V+
X-
Y-
Z-
IV-
V-
911.0
911.1
911.2
911.3
911.4
921.0
921.1
921.2
921.3
921.4
+99 999.9999
"
"
"
"
-99 999.9999
"
"
"
"
Range 3
Activation by PLC:
M2817 = 1, M2816 = 1
strobe marker M2824
X+
Y+
Z+
IV+
V+
X-
Y-
Z-
IV-
V-
912.0
912.1
912.2
912.3
912.4
922.0
922.1
922.2
922.3
922.4
+99 999.9999
"
"
"
"
-99 999.9999
"
"
"
"
R H
1.0 TNC 415B/425 Machine Parameters MP 910.0 - MP 922.4 06.03.95 5.2 8