Service manual

Function MP
No. Bit
A B C Input AE-6
Entry value
Axes with encoder
X
Y
Z
IV
V
10
0
1
2
3
4

0 = no encoder
+1 = X axis with encoder
+2 = Y axis with encoder
+4 = Z axis with encoder
+8 = IV. axis with encoder
+16 = V. axis with encoder
% 11111
Encoder monitoring
Absolute position of distance-coded
reference marks
X
Y
Z
IV
V
S
30
0
1
2
3
4
5

0 = no axis monitored
+1 = X axis monitored
+2 = Y axis monitored
+4 = Z axis monitored
+8 = IV. axis monitored
+16 = V. axis monitored
+32 = S axis monitored
% 111111
Signal amplitude
X
Y
Z
IV
V
S
31
0
1
2
3
4
5

0 = no axis monitored
+1 = X axis monitored
+2 = Y axis monitored
+4 = Z axis monitored
+8 = IV. axis monitored
+16 = V. axis monitored
+32 = S axis monitored
% 111111
Edge separation
X
Y
Z
IV
V
S
32
0
1
2
3
4
5

0 = no axis monitored
+1 = X axis monitored
+2 = Y axis monitored
+4 = Z axis monitored
+8 = IV. axis monitored
+16 = V. axis monitored
+32 = S axis monitored
% 111111
R H
1.0 TNC
415 B/425
Machine Parameters MP 10 - MP 32 03.01.95 5.2 1