Service manual

SERVICE MANUAL TNC 415B/425
Page 139
Issue: 20.08.95
Selecting the Operands and Starting the Logic Diagram
Press Key Function
A table is displayed from which the operands can be selected. The control requests the positions of the table in
a dialogue. Wrong inputs can be cleared by pressing DEL. It is possible to enter a trigger condition for each
operand. 512 states are traced before and after a trigger event. The following trigger conditions are possible:
"1" trace if the operand is a logical "1"
(trigger on positive edge)
"0" trace if the operand is a logical "0"
(trigger on negative edge)
NO
ENT
no trigger
If no trigger condition is entered for any of the operands, the operand states are traced
continuously and the last 1024 states are stored.
e.g.: 0 I5 1 trigger on positive edge
1O6 0 trigger on negative edge
2 M2003 no trigger
Start TRACE function
TNC in operating mode "MACHINE" (key on VDU)
The trace function is started with START TRACE; END TRACE or a trigger event terminate the tracing.
PCTR blinking : trigger condition has not occurred yet
PCTR on : trigger condition has occurred; write access to buffer memory
PCTR off : buffer memory is full; LOGIC DIAGRAM can be called
Switch to TRACE mode
Call logic diagram