Service manual
SERVICE MANUAL TNC 415B/425
Page 115
Issue: 20.08.95
From NC-software 259 93x.08 and 259 94x.08 the compensation values and the relations can be stored in
files with the extensions .COM and .CMA.
If there is no <NAME>.CMA file on the external data medium, the compensation value tables from the code
number 105 296 are valid. These files can be read in as described in section 17.4.4.
Press key Function
MOD
8 0 7 6 6 7
ENT
EXT
MOD
TNC in operating mode PROGRAMMING AND EDITING.
Prepare TNC for input of code number.
Enter code number, confirm with ENT.
Activate the data transfer menu.
Here, the PLC editor can be assigned to an interface.
Press soft key.
Press arrow key to enter the directory of the external data
medium.
Soft key and arrow key on VDU.
interface mode
FE1
otherwise:
...
or
Press soft key.
If necessary: press arrow key to select the desired
<NAME>.COM file.
Enter the name of the <NAME>.COM file
(ASCII or numerical keys).
Start data transfer
1)
(continued on page 116)
1)
Caution
: Until the software version 12 the dimensions "MM" must be contained after the file name in the
header of a <NAME>.COM file; otherwise the file cannot be read in (if required, use a text editor
to insert MM)
Example of a header:
BEGIN X-AXIS.COM MM DATUM:+90 DIST:2