Installation Guide

2
English
Installation Considerations
For best results, Hansgrohe recommends that
this unit be installed by a licensed, professional
plumber.
Please read over these instructions thoroughly be-
fore beginning installation. Make sure that you
have all tools and supplies needed to complete
the installation.
This showerhead is for use with rough 26909181
(not included).
Nendo showerhead 26031001 includes a low
voltage transformer.
The transformer must be connected to a properly
installed and grounded 110 V GFCI wall switch.
The switch must be installed by a licensed,
professional electrician following all applicable
local electrical codes.
The transformer must be installed in the wall in
a safe, dry, accessible location. It should be
installed in a standard electrical box larger than
2⅜" diameter (not included).
Do not install the transformer inside
the 26909181 rough.
The transformer includes 7 meters (22.9 feet) of
cable to connect the transformer to the light.
The plastic conduit included with the rough may
not be permitted by local code in some areas. In
this case, the installer must provide code compli-
ant ¾" conduit. Hansgrohe is not respon-
sible for the cost of the conduit.
To prevent scald injury, the maximum output
temperature of the shower mixing valve (not
included) must be no higher than 120°F. In
Massachusetts, the maximum output temperature
can be no higher than 112° F.
This showerhead is for use with an automatically
compensating valve rated at 8.3 L/min (2.2
GPM) or less.
Keep this booklet and the receipt (or other proof
of date and place of purchase) for this product in
a safe place. The receipt is required should it be
necessary to request warranty parts.
This unit meets or exceeds the following:
• ASME A112.18.1
• CSA B125.1
Listed by IAPMO for use in the US
and Canada
This unit meets or exceeds the following:
UL 1598, 3rd ed./ CSA C22.2
No. 250.0-08
UL 8750, 1st ed.
Listed by IAPMO for use in the US
and Canada
Technical Information
Flow rate (max) 2.5 GPM